一开科奈克cneke变压器
 home<<product information<<detailed information
KYN61-40.5 armored-away-metal exchange closed switching equipment
KYN61-40.5 armored-away-metal exchange closed switching equipment
Its short call is switch cabinet and is suitable for the three-phase exchange 50HZ 35KV single-bus and the single-bus power system. And it mainly used in the distribution power system of the power plants, substation, industrial and mining enterprises, skyscraper to receive and distribute the power, and also has the function of monitoring, controlling and protection of the circuit. It meets the standard of EC60298, GB3906, and DL404 and has the perfected “five protection” functions. It is with the away ZN85-40.5 (3AV3) type of vacuum breaker or SF type of SP series sulfur breaker, and applies the thermal insulation material and the epoxy coating technology, and thus optimizes the electrode shape, and the structure is compacted, reduces the area. The cubicle of the switch cabinet applies the high-quality aluminum zinc plate deposited by the NC after the forming of the processing through high strength bolts nut and rivet nut connecting form, component surface applies the mining spray or galvanized process. The compartment of the switch cabinet applies the metal separation sheet and has the unique pressure channel.
  • functional
  • use condition
  • applied range
  • picture
  • certification
  • 1. it applies the thermal insulation material together with the epoxy casting insulation technology
    2. it optimizes the electrode shape, and compacts the structure and narrow the area
    3. the cubicle applies the high-quality aluminum zinc plate with the connection of the high strength of bolts nut and rivet nut, and the surface of the component applies the spraying way or the zinc technology
    4. each compartment of the switch cabinet applies the metal separation sheet and has the unique pressure tunnel
  • 1. environment temperature: the max +40℃ and the min -5 ℃ (it is applicable under the temperature of -30℃)
    2. altitude: no higher than 1000m
    3. the average relative temperature is no more than 95% and the monthly average relative humidity is no more than 90%
    4. seismic intensity is no more than 8°
    5. it is also can be used in the place where is no fire, no explosion hazards, no heavy pollution and no chemical corrosion and no severe earthquake
    It also can be designed according to the detailed requirements of the users.
  • it mainly used in the distribution of power plant, substation, and industry & mining enterprises, skyscraper to receive and distribute the electric energy
  • ...
  • The state quality supervision, inspection